NEWS!!! Welcome to visit our booth, Hall 6, J48, MEDICA 2012
Reusable Silicone Laryngeal Mask Airway
I. INTENDED USE
The Laryngeal mask (LM) is a supraglottic airway management device.
II. HIGH QUALITY, FINELY DESIGN
1. Made of pure Silicone
The materials are meet the test requirements of ·USP Class VI ·ISO 10993: Cytotoxicity, Sensitization and Irritation
3. Designs for guarantee reusable performances:
·Our reusable LM meet the requirements of re-sterilization and aging test : .1 No change or damage after 40 times steam sterilization test. .2 Good performances after accelerated aging test (ASTM 1980). ·Every product with unique tracking number and record card, to avoid
confusion and ensures the correct record after use.
5. PRODUCTION QUALITY CONTROL
According to quality management system EN ISO 13485, we can guarantee the traceability of
each production process. Including purchasing, extrusion, molding, product assembly, packaging,
sterilization, inspection, in-house and delivery, until final clinical use.
III. FEATURES AND BENEFITS
- Made of pure medical grade silicone, have good biocompatibility, non-toxic. - Exclusive soft seal cuff can be insert comfortable, minimizing potential trauma and increasing sealing. - Kink-free wire-reinforced tube eliminates the risk of airway tube occlusion. - Reusable types must be cleaning and disinfection or sterilization before use, use only 40 times. - Every product with unique serial number and record card, to avoid confusion and
ensures the correct record after use. - Have different sizes, suitable for neonate, infant, children and adult.
IV. Specification
Silicone Laryngeal Mask Airway singel use & reusable.
Size | Disposable Silicone LM | Disposable Reinforced LM | Reusable Silicone LM | Reusable Reinforced LM | Patient Weight | Cuff Volume |
1.0# | PA0101 10 | PA0102 10 | PA0103 10 | PA0104 10 | < 5kg | <4ml |
1.5# | PA0101 15 | PA0102 15 | PA0103 15 | PA0104 15 | 5-10kg | <7ml |
2.0# | PA0101 20 | PA0102 20 | PA0103 20 | PA0104 20 | 10-20kg | <10ml |
2.5# | PA0101 25 | PA0102 25 | PA0103 25 | PA0104 25 | 20-30kg | <14ml |
3.0# | PA0101 30 | PA0102 30 | PA0103 30 | PA0104 30 | 30-50kg | <20ml |
4.0# | PA0101 40 | PA0102 40 | PA0103 40 | PA0104 40 | 50-70kg | <30ml |
5.0# | PA0101 50 | PA0102 50 | PA0103 50 | PA0104 50 | 70-100kg | <40ml |
6.0# | PA0101 60 | PA0102 60 | PA0103 60 | PA0104 60 | > 100kg | <50ml |
It is recommended that the Laryngeal Mask be used maximum of 40 times.
STERILIZED BY EO LATEX FREE DEHP FREE
V. Instructions for use (for clinical use only)
This product should be used by a physician or medical professional as follows:
1 The cuff inflation must be checked before use. DO NOT USE if cuff fails to inflate.2 Place on a flat surface then deflate the mask cuff with a syringe.3 The back plate of the mask should be lubricated with an appropriate lubricant.4 Make sure that the patient's head is in the 'sniffing the morning air' position.5 The laryngeal mask should be held as if holding a pen, with the open end of the
mask pointing downwards towards the tongue.6 Using an index finger for assistance, insert the laryngeal mask along the hard and
soft palate (Fig A), guiding the mask all the way through the natural bend of the
airway until feeling resistance (Fig B).7 Create a seal by inflating the mask cuff (Fig C).8 Airway patency should be confirmed by auscultation.9 If required insert a bite block and secure the mask airway.10 Connect mask to breathing circuit.
VI. Re-sterilization Methods:
1 Wash the Laryngeal Mask with soap, distilled water or NaHCO3 (saleratus).
Forbid using formaldehyde, phenol, aseptic with iodine or lubricant with silicone.2 Brush gently the airway tube.3 Wash the Laryngeal Mask cleanly with distilled water. 4 Make sure Laryngeal Mask is dry.5 Deflate all the air from Laryngeal Mask before steam autoclave.6 Steam autoclave 3 minutes at 134 C (+4 C/-0 C).
CAUTION
1 Sterilized by Ethylene Oxide (EO).
2 Recommended be used maximum of 40 times.
3 Do not exceed the recommended maximum inflation volumes.
4 Do not use if the package or product has been damaged or contaminated.
5 Do not store at extreme temperatures and humidity, avoid direct sunlight.
ODM
Special design for your requirements:
- High temperature resistant raw materials.
- Tube marking by your requirements.
- Unique tracking number and record card.
- High quality TYVEK package.
- Any other special design only for you.
VII. FIGURES
- Unique tracking number and record card
- Thin wall pilot balloon provides precise indication of inflation
- Silicone soft cuff ensuire best possible seal
ABOUT US
FORMED Focus on research & design, manufacture, quality management, global sales, technical support and OEM contract. We have three main business areas: Anaesthesia & Respiratory, Gastroenterology and Urology. The products are now sold worldwide. With sales high quality products, we also provide professional technical solutions (ODM Sevices), experiences in particular of silicone products, TPU tubes and self-use intermittent products.
FOR MEDICAL TECHNOLOGY, FOR LIFE CARE
is our first philosophy. According to quality management system EN ISO 13485, we can guarantee the traceability of each production process. Including purchasing, extrusion, molding, product assembly, packaging, sterilization, inspection, in-house and delivery, until final clinical use.
FACTORY & MACHINESWe have class 100,000 Clean Room, Laboratory, and range of manufacturing machines: Silicone mixing, Silicone Extrusion, LIM (Liquid silicone Injection Molding, Plastic Extrusion, Plastic injection molding, Plate Vulcanizing, Pad printing, Auto package sealing, etc.
Rusable Silicone Laryngeal Mask Airway